Scanning Devices
Inc.
Sensors, Instruments and Controls | 111 Terrace Hall Avenue
Burlington, Massachusetts (USA) 01803 1-781-272-5135 FAX: 1-781-272-4856 Email us: mail@scanningdevices.com |
|
The Quarter DIN II is a bi-directional registration control system with out-of-registration alarm and outputs for automatic correction. It is particularly well suited to automatic label application, insuring label position and preventing label feed if registration is not maintained. |
|||||
|
The system consists of three components:
|
|
||||
|
As the name implies, the Controller is panel-mounted in a 1/4 DIN standard cutout. Correction outputs are NPN transistors suitable to drive relays or solid-state switches for controlling correction motors. When a correction is required, the forward or reverse output energized for a time set by the front panel dials. Forward and Reverse times are independent to allow compensation for drift or stretch. Out-of-Registration control can be selected from the front panel. If selected, the controllers energizes the out-of-registration output if five consective labels are determined to be outside the registration band. The out-of-registration output may be used to sound an alarm or to interrupt label feed to prevent scrap production. Need more information? Follow this link for Installation Instructions and User Guide. (Adobe Acrobat required.) |
|||||
| 111 Terrace Hall Avenue
Burlington, Massachusetts (USA) 01803 1-781-272-5135 FAX: 1-781-272-4856 Email us: mail@scanningdevices.com |
Scanning Devices Inc. |
Home Page | Application Stories | Product Information | News | Trade Shows
CopyrightÓ 2004 Scanning Devices Inc