Scanning Devices Inc.
Sensors, Instruments and Controls
111 Terrace Hall Avenue
Burlington, Massachusetts (USA) 01803
1-781-272-5135
FAX: 1-781-272-4856
Email us: mail@scanningdevices.com


HB Registration Quarter DIN Registration Control

The Quarter DIN II is a bi-directional registration control system with out-of-registration alarm and outputs for automatic correction. It is particularly well suited to automatic label application, insuring label position and preventing label feed if registration is not maintained.

The system consists of three components:

  • Registration Mark Scanner to locate the label reference.

    Three HB scanners are available to cover a broad application range:

    • CX6A - general purpose mark scanner for most scanning situations.
    • CX7 - special purpose color contrast scanner for low contrast labels.
    • CX8 - fiberoptic scanner for small marks or hard to reach places.

  • Selector Switch that rotates with label feed to segment the label repeat into four regions:
    • In Registration, no correction required
    • Forward mark, reverse correction required
    • Reverse mark, forward correction required
    • Out-of-registration, situation required intervention.

    The selector switch consists of two optical slot scanners with a rotating flag. The switch is coupled so that the flag rotates once per label repeat. The interupters are mechanically positioned to define the four regions as the flag rotates. The selector switch is enclosed in a transparent plastic housing with mechanical adjustment accessable from the front. The transparent housing allows visual inspection during setup.

  • Quarter-Din Controller to receive input from scanner and selector switch, determine registration state and generate correction output. The controller determines the relative position of the registration mark. If not in-register, the controller generates a forward or reverse correction. The time duration of corrections is set by two independent front-panel adjustements. A manual jog switch adds to the control capability.

Quarter DIN System consists of Selector Switch, Controller, Scanner

Quarter DIN System Selector Switch

As the name implies, the Controller is panel-mounted in a 1/4 DIN standard cutout.

Correction outputs are NPN transistors suitable to drive relays or solid-state switches for controlling correction motors. When a correction is required, the forward or reverse output energized for a time set by the front panel dials. Forward and Reverse times are independent to allow compensation for drift or stretch.

Out-of-Registration control can be selected from the front panel. If selected, the controllers energizes the out-of-registration output if five consective labels are determined to be outside the registration band. The out-of-registration output may be used to sound an alarm or to interrupt label feed to prevent scrap production.

Need more information? Follow this link for Installation Instructions and User Guide. (Adobe Acrobat required.)


111 Terrace Hall Avenue
Burlington, Massachusetts (USA) 01803
1-781-272-5135
FAX: 1-781-272-4856
Email us: mail@scanningdevices.com

Scanning Devices Inc.

Home Page | Application Stories | Product Information | News | Trade Shows

 

CopyrightÓ 2004 Scanning Devices Inc